Reader · transmit Chapter 02 of 21
PLL Frequency Synthesizer
Multiplies the 20 MHz reference up to exactly 915 MHz
What it is physically
An IC on the reader PCB (e.g. ADF4350 or similar). Contains a phase-frequency detector, a charge pump, and a voltage-controlled oscillator (VCO). An external loop filter (a few R-C components) sits between the charge pump and VCO.
What it does
The VCO produces ~915 MHz. A frequency divider (÷N, where N ≈ 45) divides this down to ~20 MHz. The phase detector compares this divided signal to the crystal reference. Any phase error pumps charge into the loop filter, which tunes the VCO until the phases match. Result: f_out = N × f_ref = 45 × 20.333 MHz = 915 MHz, locked to crystal accuracy.
Why it matters
- RFID readers frequency-hop across 50 channels (902–928 MHz). The PLL retunes in microseconds to each channel.
- The PLL's phase noise becomes the reader's phase noise floor — phase-based RFID sensing needs this to be low.
- Without a PLL, you'd need a 915 MHz crystal (impractical — crystals don't go that high).
Signal at this point
Input: 20 MHz reference from crystal, ~300 mV.
Output: 915 MHz sine wave, ~0 dBm (1 mW). Frequency accuracy inherited from crystal (±20 ppm → ±18 kHz at 915 MHz).